DSpace Repository

CAM/RAD materyallerin yüzeylerine uygulanan farkli cila sistemlerinin yüzey topoğrafyasina etkisi

Show simple item record

dc.contributor.advisor Tekçe, Neslihan
dc.contributor.author Kara, Dilan
dc.date.accessioned 2022-03-04T10:40:57Z
dc.date.available 2022-03-04T10:40:57Z
dc.date.issued 2019
dc.identifier.citation Kara, Dilan, (2019). CAM/RAD materyallerin yüzeylerine uygulanan farkli cila sistemlerinin yüzey topoğrafyasina etkisi. Kocaeli: Kocaeli Üniversitesi, Diş Hekimliği Fakültesi
dc.identifier.other 531718
dc.identifier.uri http://dspace.kocaeli.edu.tr:8080/xmlui/handle/11493/12900
dc.description.abstract Bu çalışmanın amacı, farklı CAD/CAM restoratif materyallere uygulanan farklı cilalama prosedürlerinin, materyallerin yüzey özellikleri üzerinde oluşturduğu değişimin non-kontakt lazer profilometre cihazı aracılığıyla incelenmesidir. Üç farklı rezin içerikli CAD/CAM restoratif materyalinden Cerasmart (GC Corporation, Tokyo, Japonya), LAVA Ultimate (3M ESPE St Paul, MN, ABD), SHOFU (SHOFU Dental Corporation, Kyoto, Japonya), 3 mm kalınlığında, toplamda 150 adet örnek hazırlandı (n=10). Her bir Grup 5 farklı alt gruba ayrılarak, farklı cilalama prosedürlerine tabi tutuldu. Cilalama işlemleri, Grup 1: Optiglaze Color (GC Corporation, Tokyo, Japonya) Grup 2: Sof-Lex Diamond; Grup 3: Identoflex Diamond Ceramic Polisher Kit; Grup 4: Cosmedent Nano-Microhybrid Diamond Polish Kit; Grup 5: Diapolisher Pasta cila sistemleri ile üretici firmaların önerileri doğrultusunda gerçekleştirildi. Cilalama işleminin arkasından, hazırlanan örneklerin üst yüzeyleri non-kontakt lazer profilometre (Nanovea, 6 Morgan Ste 156, Irvine, CA, ABD) cihazı ile tarandı ve görüntüler elde edildi. Her bir grup için Ra, Rz ve Sa değerleri ayrı ayrı kaydedildi. Veriler tek yönlü varyans analizi (ANOVA), Kruskal Wallis Testi, Tukey ve Dunn testleri kullanılarak analiz edildi (p<0.05). Ra değerlerinde, her üç CAD/CAM materyali Cerasmart, LAVA ve SHOFU için en düşük yüzey pürüzlülük değerlerini Identoflex Diamond Ceramic Polisher Kit sistemi uygulanan örnekler sergiledi. Optiglaze Color uygulanan CAD/CAM materyallerinden LAVA ve Ceramart, SHOFU’dan daha düşük yüzey pürüzlülük değerleri sağladı. Sof-Lex Diamond Cila Sistemi uygulanan bloklarda ise CAD/CAM materyallerinden Cerasmart, LAVA ve SHOFU’dan daha düşük yüzey pürüzlülük değerleri sergiledi. Cosmedent Nano-Microhybrid Diamond Polish sistemi ve Diapolisher pasta uygulanan örneklerde LAVA en yüksek pürüzlülük değerlerini gösterdi. Sa değerlerinde, her üç CAD/CAM materyali Cerasmart, LAVA ve SHOFU için, Ra değerlerinde de olduğu gibi, en pürüzsüz yüzey topoğrafyasını Identoflex Diamond 2 Ceramic Polisher sistem sağladı. Optiglaze Color uygulanan örneklerde SHOFU en yüksek, Sof-Lex Diamond Cila Sistemi, Identoflex Diamond Ceramic Polisher sistemi, Cosmedent Nano-Microhybrid Diamond Polish sistemi ve Diapolisher pasta uygulanan örneklerde ise Cerasmart en yüksek yüzey pürüzlülük değerlerini gösterdi. Hem Ra hem Sa değerleri için, Identoflex Diamond Ceramic Polisher cila sistemi bu çalışmada kullanılan her 3 CAD/CAM materyali üzerinde en pürüzsüz yüzeyleri sağladı
dc.description.abstract To investigate the effect of different polishing procedures on surface properties of CAD/CAM resin blocks using a non-contact optical profilometer. Three different resin-based CAD/CAM restorative materials, Cerasmart (GC Corporation, Tokyo, Japan), LAVA Ultimate (3M ESPE St Paul, MN, USA) and SHOFU (SHOFU Dental Corporation, Kyoto, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs divided into three groups (n=10) Each group was divided into 5 different sub-groups and subjected to different polishing procedures. For polishing procedures Group 1: Optiglaze Color (GC Corporation, Tokyo, Japan) Group 2: Sof-Lex Diamond Polishing System; Group 3: Identoflex Diamond Ceramic Polisher; Group 4: Cosmedent Nano-Microhybrid Diamond Polish Kit; Group 5: Diapolisher Paste were used in accordance with the recommendations of the manufacturer. After the polishing, top of the surfaces of samples were prepared to screen by non-contact laser profilometer (Nanovea, 6 Morgan Ste 156, Irvine, CA, USA) to obtain the images. For each group; Ra, Rz and Sa values were recorded separately. Data were analyzed using one-way analysis of variance (ANOVA), Kruskal Wallis Test, Tukey and Dunn tests. For Ra values; For each of the three CAD/CAM materials Cerasmart, LAVA and SHOFU, the smoothest surface roughness was obtained from Identoflex Diamond Ceramic Polisher. LAVA and Cerasmart from the CAD/CAM material applied to Optiglaze Color resulted in lower surface roughness values than SHOFU. In the blocks applied Sof-Lex Diamond Polishing System, Cerasmart from CAD/CAM material; It provides lower surface roughness values than LAVA and SHOFU. LAVA exhibited the highest roughness values in the Cosmedent Porcelain Diamond Polishing System and the Diapolisher paste samples. For Sa values; for all three CAD/CAM materials Cerasmart, LAVA and SHOFU, the lowest surface topography values as well as the Ra values showed the Identoflex Diamond Ceramic Polisher system. Cerasmart showed the highest surface roughness values in the samples applied to Optiglaze Color and in the samples where the highest 3M Sof-Lex Diamond Polishing System was applied. 4 Identoflex Diamond Ceramic Polisher system for both Ra and Sa values resulted in the smoothest surfaces on every three CAD/CAM materials used in this study.
dc.language.iso tur
dc.publisher Kocaeli Üniversitesi, Diş Hekimliği Fakültesi
dc.rights openAccess
dc.subject CAD/CAM
dc.subject Cilalama
dc.subject Polishing
dc.subject Lazerler
dc.subject Lasers
dc.subject Profilometre
dc.subject Profilometer
dc.subject Yüzey pürüzlülüğü
dc.subject Surface roughness
dc.subject Yüzey topolojisi
dc.subject Surface topology
dc.subject Yüzeyler
dc.subject Surfaces
dc.subject Yüzeysel değişiklikler
dc.subject Surface changes
dc.title CAM/RAD materyallerin yüzeylerine uygulanan farkli cila sistemlerinin yüzey topoğrafyasina etkisi
dc.title.alternative The effect of different finishing/polishing procedures on the surface topography of CAD/CAM materials
dc.type specialtyThesis
dc.contributor.department Restoratif Diş Tedavisi Ana Bilim Dalı
dc.identifier.endpage 139


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account