dc.contributor.advisor |
Tekçe, Neslihan |
|
dc.contributor.author |
Bozkaya, Selen |
|
dc.date.accessioned |
2022-03-04T10:40:59Z |
|
dc.date.available |
2022-03-04T10:40:59Z |
|
dc.date.issued |
2019 |
|
dc.identifier.citation |
Bozkaya, Selen, (2019). Farklı cila sistemleri uygulanan CAD/CAM materyallerinin renk stabilitelerinin incelenmesi. Kocaeli: Kocaeli Üniversitesi, Diş Hekimliği Fakültesi |
|
dc.identifier.other |
597535 |
|
dc.identifier.uri |
http://dspace.kocaeli.edu.tr:8080/xmlui/handle/11493/12907 |
|
dc.description.abstract |
Bu çalışmanın amacı, farklı CAD/CAM materyallerin farklı cila sistemleriyle
cilalanmasının ardından, renklendirici içeceklerde bekletilerek materyallerde meydana
gelen renk değişiminin incelenmesidir.
Çalışmamızda, üç farklı rezin içerikli CAD/CAM blok Cerasmart (GC Corporation,
Tokyo, Japonya), Coltene Brilliant Crios (Coltene, Altstätten, İsviçre) ve SHOFU Blok
HC (SHOFU Dental Corporation, Kyoto, Japonya) kullanıldı. Bloklardan 2 mm
kalınlığında, toplamda 540 adet örnek hazırlandı (n=20). Çalışmada kullanılacak olan
CAD/CAM bloklar uygulanacak olan cila sistemine göre 3 ana gruba ayrıldı.
Materyallere uygulanacak olan yüzey bitirme ve cilalama sistemleri Sof-Lex Diamond
Polishing System (3M ESPE, St. Paul, Amerika), Identoflex Diamond Ceramic Polisher
(KerrHawe SA) ve Coltene Diatech Shape Guard Polishers (Coltene, Altstätten,
İsviçre)’dir. Cilalama prosedürünün arkasından örnekler tekrardan 3 alt gruba ayrıldı ve
3 farklı renklendirici solüsyonda 15 gün süresince sabah akşam olmak üzere günde 2 kez
1’er saat bekletildi. Çalışmada kullanılan içecekler filtre kahve, kola ve distile su olarak
belirlendi. Renk ölçümleri başlangıç, 1., 7. ve 15. günlerde VITA Easyshade Compact
(VITA Zahnfabrik, Bad Säckingen, Almanya) spektrometre cihazı kullanılarak yapıldı.
Veriler tek yönlü varyans analizi (ANOVA), Kruskal Wallis testi, Tukey ve Dunn testleri
kullanılarak analiz edildi (p<0.05).
Genel olarak, örneklerin içeceklerde bekletilme süresinin artması ile ΔE
değerlerinin arttığı görüldü. Her bir CAD/CAM materyali için en yüksek renk değişim
oranı kahvede bekletilen örneklerden elde edildi. 15. günün sonunda kahve ve suda
bekletilen örneklerde Cerasmart numuneleri, kolada bekletilen örneklerde ise Coltene
numuneleri en düşük renk değişim oranını sergiledi. |
|
dc.description.abstract |
The aim of this study is to investigate the color change of different CAD/CAM
materials after they are polished with different polishing systems and kept waited in
various coloring beverages.
In our study, three different resin-based CAD/CAM blocks, Cerasmart (GC
Corporation, Tokyo, Japan), Coltene Brilliant Crios (Coltene, Altstätten, Switzerland)
and SHOFU Block HC (SHOFU Dental Corporation, Kyoto, Japan), were used. A total
of 540 samples with 2 mm thickness were prepared from the blocks. CAD/CAM blocks
that were going to be used in the study were divided into 3 main groups according to the
polishing system. Surface finishing and polishing systems applied to materials were SofLex Diamond Polishing System (3M ESPE, St. Paul, USA), Identoflex Diamond Ceramic
Polisher (KerrHawe SA) and Coltene Diatech Shape Guard Polishers (Coltene, Altstätten,
Switzerland). After the polishing procedure, the samples were divided again into 3 subgroups and kept waited in 3 different coloring solutions for 1 hour twice a day during
morning and evening for 15 days. Beverages used in the study were selected as filtered
coffee, cola and distilled water. Color measurement was performed at the begining, 1st,
7th and 15th days using VITA Easyshade Compact spectrometer device. Data was
analyzed using one-way analysis of variance (ANOVA), Kruskal Wallis, Tukey and
Dunn tests.
It was observed that the ΔE value is proportionally increasing with the increase of
waiting time inside coloring beverages. The highest color change for each CAD/CAM
material was obtained from the samples kept in coffee. At the end of 15 days, Cerasmart
samples showed the lowest color change for coffee and water, where Coltene samples
showed the lowest color change for cola. |
|
dc.language.iso |
tur |
|
dc.publisher |
Kocaeli Üniversitesi, Diş Hekimliği Fakültesi |
|
dc.rights |
openAccess |
|
dc.subject |
CAD/CAM |
|
dc.subject |
Dental cilalama |
|
dc.subject |
Dental polishing |
|
dc.subject |
Dental materyaller |
|
dc.subject |
Dental materials |
|
dc.subject |
Diş renk değişikliği |
|
dc.subject |
Tooth discoloration |
|
dc.subject |
Kahve |
|
dc.subject |
Coffee |
|
dc.subject |
Kola |
|
dc.subject |
Cola |
|
dc.subject |
Kompozit reçineler |
|
dc.subject |
Composite resins |
|
dc.subject |
Renk değişikliği |
|
dc.subject |
Color change |
|
dc.subject |
İçecekler |
|
dc.subject |
Beverages |
|
dc.title |
Farklı cila sistemleri uygulanan CAD/CAM materyallerinin renk stabilitelerinin incelenmesi |
|
dc.title.alternative |
Examination of color stability of CAD / CAM materials applied with different polishing system |
|
dc.type |
specialtyThesis |
|
dc.contributor.department |
Protetik Diş Tedavisi Ana Bilim Dalı |
|
dc.identifier.endpage |
98 |
|