DSpace Repository

Çok parçalı le fort I osteotomileri ile oluşturulan kemik segmentlerinde ve titanyum fiksasyon sistemlerinde çiğneme kuvvetleri altında meydana gelen stres dağılımının üç boyutlu sonlu eleman analizi ile incelenmesi

Show simple item record

dc.contributor.advisor Kan, Bahadır
dc.contributor.author Bayramoğlu Sürmelioğlu, Deniz
dc.date.accessioned 2022-03-04T10:41:06Z
dc.date.available 2022-03-04T10:41:06Z
dc.date.issued 2016
dc.identifier.citation Bayramoğlu Sürmelioğlu, Deniz, (2016). Çok parçalı le fort I osteotomileri ile oluşturulan kemik segmentlerinde ve titanyum fiksasyon sistemlerinde çiğneme kuvvetleri altında meydana gelen stres dağılımının üç boyutlu sonlu eleman analizi ile incelenmesi. Kocaeli: Kocaeli Üniversitesi, Diş Hekimliği Fakültesi
dc.identifier.other 445237
dc.identifier.uri http://dspace.kocaeli.edu.tr:8080/xmlui/handle/11493/12927
dc.description.abstract Üç Boyutlu Sonlu Eleman Analiz (SEA) yöntemi kullanılarak 1, 2, 3, 4 parçalı segmental Le Fort I osteotomileri sonrası çiğneme kuvvetlerinin etkisiyle kemik segmentlerde ve titanyum fiksasyon sistemlerinde meydana gelen stres birikimleri ölçülerek, bunlara bağlı kemik segmentlerin ve fiksasyon sistemlerinin instabilite durumlarının karşılaştırmalı olarak incelenmesi. Maksiller gelişim geriliği bulunan bir hastanın DICOM dataları alınarak maksiller kemiğin 3 boyutlu modellemesi MIMICS programıyla yapıldı. Kontrol modeli olarak daha önce SARPE operasyonu ile 5 mm maksiller genişletme yapılmış modelde geleneksel Le Fort I osteotomisiyle maksilla 5 mm ileri alındı. Deney grubuna 2, 3 ve 4 parçalı Le Fort I teknikleri uygulanarak maksillaya 5 mm genişletme ve 5 mm ilerletme yapılıp zigomatikomaksiller desteklerden ve apertura piriformis bölgesinden 2 adet 1,7 mm standart 5 delikli L plaklar ve kanin-1. premolar dişlerin vestibülünden 4 delikli düz plaklar, 1,6 mm çapında ve 5 mm uzunluğunda titanyum vidalar ile SolidWorks programında sabitlendi. Molar bölgesinden 250 N ve kesici dişler bölgesinden 125 N olarak uygulanan modellerin ANSYS programı ile SEA analizleri yapıldı. Pmax değeri kortikal kemikte ön kuvvetlerde model 3’teki düz plağın 2. ve 4. vida bölgesinde, kanselöz kemikte 4. modeldeki düz plağın 4. vida bölgesinde; Von Mises değeri ön kuvvetlerde model 3’te düz plağın 2. vida bölgesinde, Pmin değeri kortikal kemikte ön kuvvetlerde model 3’deki düz plağın 4. Vida bölgesinde, kanselöz kemikte ön kuvvetlerde model 4’teki düz plağın 4. vida bölgesinde, total deformasyon miktarı ön kuvvetlerde model 3 ve 4’te maksiller alt ön segmentte ölçülmüştür. Model 3 ve 4’te, model 1 ve 2 ‘ye göre yüksek stres biriktiği, model 1 ve 2’nin daha stabil olduğu, plaklardaki en yüksek stresin büküm yerlerinde olduğu, düz plakların 4 delikli standart plak yerine güçlendirilmiş modifiye plaklar olması gerektiği, daha fazla klinik çalışmaya ihtiyaç olduğu görülmüştür.
dc.description.abstract Three Dimensional Finite Element Analysis (FEA) of the bone segments and the titanium fixation systems formed by 1, 2, 3, 4 piece segmental Le Fort I osteotomies for a comparative study of the instabilities, based on the measurements of the accumulation of stress on these bone segments and fixation systems due to the force of mastication. DICOM data from a patient with retarded maxillary development has been taken and the MIMICS software has been used for 3 dimensional modelling of the maxillary bone. As the control model, the maxilla was advanced by 5 mm on a model with previous 5 mm maxillary widening through the SARPE operation. 2, 3 and 4 piece Le Fort I technique was applied to the experiental group for 5 mm maxillary expansion and 5 mm maxillary advancement, and titanium screws 1,6 mm in radius and 5mm in length were used to fix two 1,7 mm standard 5 hole L plates from the zygomaticomaxillary buttress and the pyriform aperture area and 4 hole flat plates from the vestubulum of the Canine1. Premolar teeth in the SolifWorks software. ANSYS software was used for FEA analyses of models applied as 250 N from the molar area and 125 N from the incisor area. The following has been measured: Pmax value on the 2nd and 4th screw area of the flat plane in model 3 for frontal forces on cortical bone, the 4th screw area of the flat plate in model 4 for the cancellous bone, Von Mises value for frontal forces in model 3 on the 2nd screw area of the flat plate. Pmin value on the 4th screw area of the flat plate in model 3 for frontal forces on the cortical bone and 4th screw area of the flat plate in model plate for cancellous bone. Total deformation amount on the lower frontal maxillary area in model 3 and 4 for frontal forces. It has been observed that more stress develops in models 3 and 4 compared to the models 1 and 2, that the highest stress on the plates occurs on the bending points, that the flat plates should be modified reinforced plates instead of the 4 hole standard plates and that more clinical studies are needed.
dc.language.iso tur
dc.publisher Kocaeli Üniversitesi, Diş Hekimliği Fakültesi
dc.rights openAccess
dc.subject Alveolar kenar artırılması
dc.subject Alveolar ridge augmentation
dc.subject Dental stres analizi
dc.subject Dental stress analysis
dc.subject Maksilla
dc.subject Maxilla
dc.subject Osteotomi
dc.subject Osteotomy
dc.subject Sonlu elemanlar analizi
dc.subject Finite element analysis
dc.title Çok parçalı le fort I osteotomileri ile oluşturulan kemik segmentlerinde ve titanyum fiksasyon sistemlerinde çiğneme kuvvetleri altında meydana gelen stres dağılımının üç boyutlu sonlu eleman analizi ile incelenmesi
dc.title.alternative Three dimensional finite element analysis of the stress distribution under the force of mastication over the bone segments and the titanium fixation systems formed by the multiple piece le fort i osteotomy
dc.type specialtyThesis
dc.contributor.department Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı
dc.identifier.endpage 116